DAT210 Inverter Assembly with Power Conditioning Module (PCM) 208-240V (code 70250-4 120v, 70250-5 220v)
The DAT210 Inverter Assembly solves several circuit problems that shorten component life and simplifies assembly of products at an install site. For use with 240v 3Ø, 25 amp max or 240v single phase. To optimize power factor correction for other currents, see this table.
1.) Positive power output to DAT210 board. Connects to "+BUS" 0.25" quick connect tab on circuit board.
2.) Negative power output to DAT210 board. Connects to "-BUS" 0.25" quick connect tab on circuit board.
3.) Incoming 3 phase power. 0.25" quick connect tabs. Customer supplied fusing required.
4.) AC reference signal to DAT210 board. Connect to "INPUT" connector (CON2) on circuit board.
Connection polarity for 5V dc to Con3 is critical. Incorrect wiring will damage the board !
Wire guage of 22awg is recommended.
1. Pin 1 is for the negative 5Vdc connection. This should be connected to pin 3 on the 16 pin
connector on the DAT210 board (marked as CON12 on the circuit board).
2. Pin2 is for the positive 5Vdc connection. This should be connected to pin 5 on the 16 pin
connector on the DAT210 board.
3. Alternately : connect to customer PLC for soft charge management. Polarity is critical !!!
Plasma Technics, Inc.® (PTI) assumes no responsibility or liability for specific applications results.